1.
Radiol. bras ; 54(1): 21-26, Jan.-Feb. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1155228

ABSTRACT

Abstract Objective: To validate the use of a three-dimensional printing system for metric and volumetric analysis of the segments of an abdominal aortic aneurysm (AAA). Materials and Methods: In patients scheduled to undergo endovascular AAA repair, the computed tomography angiography (CTA) measurements obtained during the preoperative assessment of the patients were compared with those obtained by computed tomography of individualized three-dimensional biomodels. Results: The volumetric assessment showed a discrepancy of 3-12%, and the difference between the areas was 10-16%. Conclusion: Computed tomography measurements of 3D-printed biomodels of AAAs appear to be comparable to those of threedimensional CTA measurements of the same AAAs, in terms of the metric and volumetric dimensions.


Resumo Objetivo: Validar a aplicação do método de impressão tridimensional de biomodelos para aferição métrica e volumétrica de segmentos de aneurisma de aorta abdominal. Materiais e Métodos: Compararam-se as medidas obtidas por tomografia computadorizada dos biomodelos tridimensionais com as realizadas no planejamento pré-operatório de pacientes submetidos a correção endovascular de aneurisma de aorta abdominal. Resultados: A avaliação da volumetria demonstrou discrepância de 3% a 12% e a diferença entre as áreas foi de 10% a 16%. Conclusão: A tomografia computadorizada dos biomodelos impressos é compatível nas aferições métricas e volumétricas com as imagens tridimensionais da angiotomografia do paciente.

2.
Rev. bras. cir. cardiovasc ; 29(4): 527-536, Oct-Dec/2014. tab, graf
Article in Portuguese | LILACS, SES-SP | ID: lil-741734

ABSTRACT

Introdução: O manejo das doenças da aorta torácica que envolvem a aorta ascendente, arco aórtico e aorta torácica descendente constituem um desafio técnico e é uma área em constante desenvolvimento e inovação. Objetivo: Analisar os resultados iniciais e a médio prazo do tratamento híbrido das doenças do arco aórtico. Métodos: Estudo retrospectivo de procedimentos realizados no período de janeiro de 2010 a dezembro de 2012, em que foram analisados o sucesso técnico e terapêutico, a morbimortalidade, os desfechos neurológicos, a taxa de vazamentos e de reintervenções. Resultados: Em um total de 95 pacientes tratados por doenças da aorta torácica no período, 18 realizaram o tratamento híbrido e adentraram neste estudo. A idade média foi de 62,3 anos. O sexo masculino esteve presente em 66,7%. O sucesso técnico e terapêutico foi de 94,5% obe 83,3%, respectivamente. A mortalidade perioperatória foi de 11,1%. Não houve óbito durante o acompanhamento de 1 ano. A taxa de reintervenção foi de 16,6%, devido a 2 casos de endoleak tipo Ia e um caso de endoleak tipo 2. Não foi observada oclusão dos enxertos anatômicos ou extra-anatômicos durante o período de seguimento. Conclusão: O tratamento híbrido das doenças do arco aórtico demonstrou ser uma alternativa viável à cirurgia convencional. As taxas de sucesso terapêutico e de reintervenções demonstram a necessidade do seguimento clínico rigoroso desses pacientes a longo prazo. .


Introduction: The management of thoracic aortic disease involving the ascending aorta, aortic arch and descending thoracic aorta are technically challenging and is an area in constant development and innovation. Objective: To analyze early and midterm results of hybrid treatment of arch aortic disease. Methods: Retrospective study of procedures performed from January 2010 to December 2012. The end points were the technical success, therapeutic success, morbidity and mortality, neurologic outcomes, the rate of endoleaks and reinterventions. Results: A total of 95 patients treated for thoracic aortic diseases in this period, 18 underwent hybrid treatment and entered in this study. The average ages were 62.3 years. The male was present in 66.7%. The technical and therapeutic success was 94.5% e 83.3%. The perioperative mortality rate of 11.1%. There is any death during one-year follow- up. The reoperation rates were 16.6% due 2 cases of endoleak Ia and one case of endoleak II. There is any occlusion of anatomic or extra anatomic bypass during follow up. Conclusion: In our study, the hybrid treatment of aortic arch disease proved to be a feasible alternative of conventional surgery. The therapeutic success rates and re- interventions obtained demonstrate the necessity of thorough clinical follow-up of these patients in a long time. .


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aorta, Thoracic/surgery , Aortic Diseases/surgery , Endovascular Procedures/methods , Aorta, Thoracic/diagnostic imaging , Aortic Diseases/mortality , Aortic Diseases/diagnostic imaging , Postoperative Complications , Time Factors , Angiography/methods , Tomography, X-Ray Computed/methods , Stents , Retrospective Studies , Risk Factors , Treatment Outcome , Carotid Artery, Common/surgery , Carotid Artery, Common/diagnostic imaging , Endoleak/etiology , Endovascular Procedures/mortality , Intraoperative Complications , Medical Illustration
3.
Rev. bras. cardiol. invasiva ; 22(1): 99-101, Jan-Mar/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-712731

ABSTRACT

Há vários anos, a oclusão percutânea do canal arterial persistente é uma técnica factível e eficaz na maioria das variantes morfológicas descritas por Krishenko. O tipo B, em janela, caracterizado por ser curto, permanece um desafio, devido ao maior risco de embolizações das próteses e das oclusões incompletas. Descrevemos aqui o uso bem-sucedido de oclusores septais AMPLATZER® em três pacientes com canal arterial em janela, dois casos tratados com dispositivos de 5 mm e um com o de 7 mm. O dispositivo AMPLATZER® desenhado para a oclusão da comunicação interatrial mostrou-se eficaz para o tratamento percutâneo dessa variante morfológica de canal arterial persistente.


For several years the percutaneous closure of patent ductus arteriosus has been a reliable and effective technique for most of the morphologic variants described by Krichenko. Type B, or window-type, patent ductus arteriosus remains a challenge due to the higher risk of device embolizations and incomplete occlusions. We report the successful use of AMPLATZERTM septal occluder in three patients with window-type patent ductus arteriosus, two cases treated with a 5-mm device and one case with a 7-mm device. The AMPLATZERTM device designed for the occlusion of atrial septal defects is effective for the percutaneous treatment of this morphological variant of patent ductus arteriosus.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Blood Vessel Prosthesis Implantation , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/genetics , Angiography/methods , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/genetics , Heart Septal Defects/surgery , Heart Septal Defects/genetics
4.
São Paulo; s.n; 2014. [72] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-750126

ABSTRACT

Introdução: Apesar de bons resultados descritos na literatura, o substituto ideal para a utilização como remendo no fechamento arterial ainda não existe. Por este motivo, ainda há espaço para a busca por remendo que seja biocompatível, e que apresente facilidade de manuseio e resultados satisfatórios. Avaliamos remendos arteriais de silicone (polidimetilsiloxano com reforço em poliéster - PDMSr) em comparação com remendos arteriais de PTFEe. Objetivo: O objetivo deste trabalho é comparar, em modelo experimental, em coelhos, os resultados de remendos arteriais feitos em PDMSr com remendos de PTFEe. Materiais e Método: A amostra foi definida em 10 animais que completassem todas as etapas da pesquisa em cada grupo. Os animais foram submetidos à laparotomia mediana e abertura longitudinal da aorta de aproximadamente 8mm, realizando-se o seu fechamento com remendo do grupo selecionado, seguido do fechamento por planos. Os animais foram mantidos em biotério até o 60º PO, quando, então, realizou-se arteriografia de controle, e análise macro e microscópica de peça. Resultados: Para se atingir a amostra desejada, foram necessários 12 procedimentos no grupo PDMSr e 16 no grupo PTFEe. Ocorreram 2 óbitos no grupo PDMSr e 6 no grupo PTFEe. Apesar do número maior de óbitos no grupo PTFEe não houve diferença estatística na sobrevida entre os grupos. Um animal do grupo PDMSr apresentou monoparesia em pata posterior direita e um animal do grupo PTFEe apresentou hérnia incisional. Não houve diferença estatística nas complicações entre os grupos. O tempo operatório foi estatisticamente maior no grupo PTFEe quando comparamos todos os animais, fato que não se repetiu quando excluímos os animais que faleceram...


Introduction: Although good results are reported for various materials for use as patches for arterial closure, as yet none of these is ideal. Therefore, research is continuing into development of a patch that is biocompatible and provides ease of handling, while having satisfactory outcomes. A new silicone arterial patch (polydimethylsiloxane reinforced with polyester fabric, PDMSr) was compared with patches made of expanded polytetrafluoroethylene (ePTFE). Objective: To compare the outcomes between arterial patches made of PDMSr with those made of ePTFE, in an experimental rabbit model. Materials and Method: Rabbits were placed in two groups, and received either PDMSr or ePTFE arterial patches (PDMSr group and ePTFE group, respectively). The animals underwent laparotomy and longitudinal opening of the aorta, which was then closed with the selected patch, followed by suture of all layers. The animals were kept in their cages until the 60th postoperative day, when arteriography, removal of the aorta, and macroscopic and optic and scanning electron microscopic analyzes of the aorta were performed. Ten rabbits from each group that had completed all stages of the research were included in analyses. Results: Twelve procedures were performed in the PDMSr group and 16 in the ePTFE group. There were 2 deaths in the PDMSr group and 6 in the ePTFE group. Despite the higher number of deaths in the ePTFE group, there was no statistical difference in survival rate between the groups. One animal in the PDMSr group developed monoparesis in its right hind paw and 1 animal in the ePTFE group had an incisional hernia. There was no statistical difference in complications between the groups. The operative time was significantly longer in the ePTFE group when all animals were included in analysis, but not when animals that died were excluded...


Subject(s)
Animals , Female , Rabbits , Aorta, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation , Dimethylpolysiloxanes , Endothelium, Vascular , Polyesters , Polytetrafluoroethylene , Silicones , Vascular Grafting , Vascular Patency , Implants, Experimental , Rabbits
5.
J. vasc. bras ; 12(1): 62-67, jan.-mar. 2013. ilus
Article in Portuguese | LILACS | ID: lil-670391

ABSTRACT

O rim em ferradura é uma das anomalias urológicas congênitas mais comuns e está presente em cerca de 0,12% dos pacientes com aneurisma de aorta abdominal. O reparo cirúrgico convencional está associado a dificuldades técnicas que provavelmente aumentam a morbidade e a mortalidade, mas que podem ser evitadas com o tratamento endovascular. Relatamos um caso de um paciente de 64 anos com rim em ferradura e aneurisma de aorta abdominal, que foi submetido ao reparo endovascular do aneurisma com sucesso.


The horseshoe kidney is one of the most common urologic anomalies and is present in about 0,12% of the patients with abdominal aortic aneurysm. The conventional surgical repair is associated with technical difficulties that probably increase morbidity and mortality, but can be averted by the endovascular treatment. We report a case of a 64-year-old patient with horseshoe kidney and abdominal aortic aneurysm, who underwent endovascular repair with success.


Subject(s)
Humans , Male , Aged , Aortic Aneurysm, Abdominal/congenital , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Kidney/abnormalities , Angioplasty/methods , Physical Examination/nursing
6.
Rev. bras. cir. cardiovasc ; 25(3): 303-310, jul.-set. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-564995

ABSTRACT

INTRODUÇÃO: O tratamento híbrido das lesões complexas da aorta torácica (LCAT) requer a revascularização de uma ou mais artérias supra-aórticas, seguida do implante de endoprótese, com morbidade e mortalidade presumidamente mais baixas que a cirurgia convencional. OBJETIVOS: Avaliar a técnica e resultados do tratamento híbrido das LCAT. MÉTODOS: Durante dois anos, 12 pacientes com LCAT foram submetidos a procedimentos híbridos, incluindo aneurismas do arco aórtico e dissecções aórticas agudas Stanford A e B. Todos possuíam indicação de tratamento invasivo, além de zona de ancoragem proximal inadequada (menor que 20 mm). Metade era do sexo masculino e a média de idade de 55,5 anos (42 a 78). Pelo menos três fatores de risco cardiovascular estavam presentes em 75 por cento dos pacientes. A média de seguimento foi de 10,9 meses (2 a 25), com acompanhamento clínico e tomográfico. RESULTADOS: O sucesso técnico inicial foi alcançado em 10 pacientes. Todas as derivações dos vasos supra-aórticos foram realizadas em ambiente cirúrgico e os procedimentos endovasculares em sala de radiologia vascular. A "técnica do varal" foi empregada em seis casos. Dois óbitos ocorreram nos primeiros 30 dias do procedimento. Nenhuma migração da endoprótese foi observada. Nenhum paciente apresentou paraplegia, acidente vascular cerebral, insuficiência renal, hemorragia ou coagulopatia, conversão cirúrgica eletiva ou de emergência. CONCLUSÃO: O tratamento híbrido das LCAT é viável, especialmente em pacientes de alto risco. Uma adequada integração das técnicas cirúrgica e endovascular, além do acompanhamento clínico e radiológico adequado, tornam esta técnica uma ótima opção à cirurgia convencional.


BACKGROUND: Hybrid procedures for the treatment of complex thoracic aortic diseases (CTAD) require the revascularization of one or more supra-aortic arteries, followed by the deployment of one or more aortic endoprosthesis, with lower morbidity and mortality compared to conventional surgery. OBJECTIVES: To evaluate the technique and results of hybrid procedures for CTAD. METHODS: During two years, 12 patients with CTAD underwent hybrid procedures, including aortic arch aneurysms and acute Stanford A and B aortic dissections. All patients had formal indications to invasive treatment, and inadequate proximal landing zone (less than 20 mm). Half were male and the mean age was 55.5 years (42 to 78). At least three cardiovascular risk factors were present in 75 percent of patients. The average follow-up was 10.9 months (2 to 25), with periodic consultations and CT scans. RESULTS: The initial technical success was achieved in 10 patients. Bypasses of supra-aortic vessels were performed in a surgical environment and endovascular procedures in an interventional radiology facility. "Through-and-through" technique was used in six patients. Two deaths occurred in the first 30 days after the procedure. No endoprosthesis migration was observed. No patient had paraplegia, stroke, renal failure, bleeding or coagulopathy, elective or emergency surgical conversion. CONCLUSION: Hybrid treatment of CTAD is feasible, especially in high risk patients. Proper integration of surgical and endovascular techniques, in addition to clinical and radiological surveillance, makes this technique a great alternative to conventional surgery.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Aortic Dissection/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Aortography , Longitudinal Studies , Retrospective Studies , Time Factors , Treatment Outcome
7.
Rev. bras. cir. cabeça pescoço ; 39(3)jul.-set. 2010. ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-570091

ABSTRACT

Introdução: A ressecção dos vasos carotídeos devido aparagangliomas é um procedimento de exceção. Pacientese Método: Os prontuários médicos de 39 pacientes foramrevisados retrospectivamente. Em seis casos, a ressecção daartéria carótida interna foi realizada para remoção completado tumor. Resultados: Havia três pacientes masculinos e trêsfemininos. A idade ao diagnóstico variava de 23 a 46 anos,com mediana de 28 anos. Em cinco pacientes, o tumor eraunilateral, sendo quatro à direita e um a esquerda. Um pacienteapresentava tumor bilateral. A avaliação pré-operatória foirealizada por tomografia computadorizada em todos os pacientese, em três casos, associou-se a angiografia. Em seis pacientes,não foi possível a dissecção através do plano subadventicial ea ressecção vascular foi necessária para remoção completado tumor. Optou-se pelo uso de um enxerto de safena ouprótese sem uso de shunts temporários. O tempo médio declampeamento dos vasos foi de 35 minutos. Apenas um pacienteapresentou complicação neurológica pós-operatória e estafoi temporária. Não houve qualquer caso de lesão isquêmicacerebral ou sequela permanente, bem como recorrências locaisou metástases a distância. Conclusão: Em alguns pacientes, oplano subadventicial estará obliterado pelo tumor. Nesta situação,a remoção completa do tumor pode exigir ressecção da artériacarótida interna. A nossa escolha, nestes casos, é a reconstruçãoimediata com o uso de um enxerto de veia safena e sem o uso deshunts temporários.


Introduction: Vascular resection due to paragangliomas is arare procedure. Patients and Method: The medical charts of39 patients were retrospectively reviewed. In six patients, theinternal carotid artery was resected for complete removal of thetumor. Result: There were three males and three females. Age atdiagnosis ranged from 23 to 46 years (median, 28 years). In fivepatients, there was a unilateral tumor, four on the right side andone on the left and one patient presented a bilateral tumor. Preoperativeevaluation was performed through CT scan in all patientsand angiography in three. Dissection through the subadventittialplane wasn?t possible in six patients and vascular resection wasnecessary for complete tumor removal. Saphenous vein grafts orprotheses were used in all patients, with a mean clamp time of 35minutes. One patient presented a transient neurologic sequela. Nopermanent deficit or ischemic stroke was recorded. Conclusion:The subadventitial plane may be obliterated in some patientsand complete tumor removal will mandate internal carotid arteryresection. Our choice in these cases is immediate reconstructionwith a saphenous vein or prothesis interposition between thevascular stumps.

8.
J. vasc. bras ; 8(4): 327-334, dez. 2009. tab, ilus
Article in English | LILACS | ID: lil-543400

ABSTRACT

A long way was traveled since the first surgery was performed for the treatment of abdominal aortic aneurysm. Throughout this time, several innovations have been created in order to reduce the invasiveness of the surgical procedures and to improve their safety and durability. This review discusses the major and recent advances on aortic aneurysm interventions, including, the endovascular aortic repair, the laparoscopic aortic surgery, the conventional hybrid and endovascular techniques, combined laparoscopic and endovascular techniques, as well as future prospects for both thoracic and abdominal aorta. Faced with so many changes and developments, modern vascular surgeons must keep their minds open to innovations and should develop comprehensive training with different techniques, to provide the best therapeutic option for their patients.


Um longo caminho foi percorrido desde as primeiras intervenções cirúrgicas feitas para o tratamento do aneurisma de aorta abdominal. Ao longo deste tempo, várias inovações foram criadas, no sentido de reduzir a invasividade dos procedimentos e melhorar sua segurança e durabilidade. Nesta revisão, são discutidos os principais e recentes avanços em intervenções sobre aneurismas aórticos, incluindo a restauração aórtica endovascular, a cirurgia aórtica videolaparoscópica, as técnicas híbridas convencionais e endovasculares, as técnicas combinadas videolaparoscópicas e endovasculares, bem como as perspectivas futuras, tanto para aorta torácica como abdominal. Diante de tantas transformações e evolução, o cirurgião vascular moderno terá que ter sua mente aberta para as novidades e desenvolver capacitação ampla com diferentes técnicas para proporcionar a melhor opção terapêutica para seus pacientes.


Subject(s)
Humans , Aneurysm/surgery , Aneurysm/complications , Aneurysm/diagnosis , Aorta/surgery , Blood Vessel Prosthesis Implantation
9.
Rev. bras. cir. cardiovasc ; 23(3): 425-428, jul.-set. 2008. ilus
Article in English, Portuguese | LILACS | ID: lil-500533

ABSTRACT

O rim em ferradura é uma anomalia congênita rara que pode causar várias dificuldades técnicas durante a correção convencional de aneurisma de aorta abdominal. Relatamos o caso de uma paciente de 68 anos com rim em ferradura, aneurisma de aorta abdominal sintomático e disfunção renal leve. A paciente foi submetida a correção endovascular, sendo utilizada uma endoprótese bifurcada. O pós-operatório foi livre de complicações. O diagnóstico e a técnica endovascular são discutidos, assim como a literatura revisada.


Horseshoe kidney is a rare congenital anomaly that may cause various technical problems during conventional repairs of abdominal aortic aneurysms. We report the case of a 68-year-old woman with a horseshoe kidney, symptomatic abdominal aortic aneurysm and mild renal failure. The patient underwent endovascular repair using a bifurcated endoprosthesis. The postoperative was uneventful. We describe the diagnosis and the endovascular technique and literature review.


Subject(s)
Aged , Female , Humans , Aortic Aneurysm, Abdominal/surgery , Kidney/abnormalities , Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Iliac Artery , Iliac Artery/surgery , Kidney , Vascular Surgical Procedures/methods
10.
Rev. Col. Bras. Cir ; 35(4): 252-258, jul.-ago. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-494172

ABSTRACT

OBJETIVO: Avaliar e comparar a resposta tecidual de uma endoprótese biosintetica implantada na aorta torácica descendente e veia cava inferior de suínos. MÉTODO: Foi implantada uma endoprótese auto-expansível composta de aço inoxidável, revestida por veia jugular de bovino, processada pelo método L-hydro, com auxilio de uma bainha de liberação Taheri-Leonhardt (Flórida, EUA) na aorta torácica descendente, e a veia cava infra-renal de 10 suínos. Sessenta dias após, as endopróteses foram retiradas e analisadas sob o ponto de vista macro e microscópicos. Foram observados: perviedade, grau de incorporação a parede do vaso, tipo de reação inflamatória, e local de maior resposta, tanto em relação a camada do vaso quanto ao local de contato com o anel de aço RESULTADOS: Todas as endopróteses encontravam-se pérvias, e incorporadas à parede. No setor venoso, seis apresentaram traves fibrosas em sua luz, e quatro apresentaram fibrose perivascular. No setor arterial somente uma prótese apresentou discreta estenose, sem fibrose perivascular. A reação inflamatória crônica tipo corpo estranho ocorreu em 100 por cento das peças, a camada média foi a mais acometida no setor venoso, enquanto a íntima foi mais constante na artéria, o grau de incorporação foi mais firme na veia em comparação a artéria. A reação tecidual mostrou maior tendência nas áreas em intimo contato com o anel de aço (intra-anelar), mais intensa na artéria do que na veia. CONCLUSÃO: A prótese apresentou baixa trombogenicidade em ambos os sistemas, houve maior reação tecidual e baixa biocompatibilidade no setor venoso.


BACKGROUND: To evaluate and compare the tissue response, in swine, to a biosynthetic stent-graft when implanted in both thoracic aorta and inferior vena cava. METHOD: It was used a self-expanding stainless stent, covered by segment of bovine jugular veins, processed by the method L-hydro, and delivered by Taheri-Leonhardt system (Florida, USA) . The implants were done in the descending thoracic aorta, and in the infra-renal vena cava of 10 swines. Sixty days after, the endoprosthesis were removed and analyzed under macro and microscopic view. The following parameters were analyzed: patency, incorporation to the vessel wall, type of inflammatory reaction, tissue response concerning the layer of the vessel as for the contact with the ring steel. RESULTS: All implanted stent-grafts were patent, and incorporated to the vessel wall. Six presented fibrous bars, and four presented perivascular fibrosis at the venous section. At the arterial section, only one prosthesis developed a very small stenosis, without perivascular fibrosis. We observed chronic inflammatory reaction with a foreign body granulomatous response in 100 percent of the samples, the medium layer was the more prevalent at the vein section, while the intima layer was more constant at the artery, venous incorporation was stronger than artery incorporation, and tissue response was enhanced in the inner contact between the vessel wall and the ring steel. CONCLUSION: The prosthesis in study presented low thrombogenicity in both systems. It was also present, larger tissue response and low biocompatibility at the venous system, and better biocompatibility at the arterial system.

11.
São Paulo; s.n; 2005. 59 p. ilus, graf, tab.
Thesis in Portuguese | LILACS | ID: lil-586992

ABSTRACT

Objetivo: Medir a pulsatilidade da parede do aneurisma de aorta humano antes e depois de sua correção endoluminal. Método: Cinco aneurismas foram submetidos à perfusão pulsátil antes e depois do implante de uma endoprótese. Resultado: o nível da coluna de água oscilou durante a pulsação com variações de 17, 16, 13, 7 e 25 cm antes da colocação da endoprótese. Depois da prótese, a oscilação diminuiu em todos os casos para 13, 12, 9, 3,5 e 23 cm, respectivamente. Conclusão: A pulsação da endoprótese é transmitida à parede do aneurisma.


Objective: To measure the pulsatility of human aortic aneurysms before and after exclusion with endograft. Method: Five aneurysms were submitted to pulsatile perfusion before and after implantation of a bifurcated endograft. Result: The level of the water column oscillated during pulsation, in each case, with an amplitude of 17, 16, 13, 7 and 25 cm before the endograft insertion. After that, the amplitudes dropped to, respectively 13, 12, 9, 3.5 and 23 cm.Conclusion: Pulsation of an endograft is transmitted to the aneurysm wall even in the absence of endoleak.


Subject(s)
Humans , Aortic Aneurysm/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation , Cadaver , Humans , Pulsatile Flow
12.
Rev. méd. Minas Gerais ; 14(3): 171-172, jul.-set. 2004.
Article in Portuguese | LILACS | ID: lil-576346

ABSTRACT

A insuficiência venosa superficial atinge 10% a 20% da população ocidental. Até pouco tempo, o principal tratamento cirúrgico era a remoção das veias varicosas, inclusive da veia safena magna que constitui o principal eixo de drenagem venosa superficial. Atualmente, há uma nova possibilidade de tratamento cirúrgico: a valvuloplastia externa de junção safeno-femoral, que se caracteriza por reforço externo à parede venosa enfraquecida.


Chronic superficial venous insufficiency affects 10-20% of the population of the Western World. Until recently, the main form of surgical treatment was the removal of the varicose veins, including the main stem of the long saphenous vein. Presently, a new technique exists external valvuloplasty of the sapheno-femoral junction with a venocuff consisting of a sleeve wrapped around the incompetent valve.


Subject(s)
Humans , Catheterization , Varicose Veins/surgery , Saphenous Vein/surgery , Retrospective Studies
SELECTION OF CITATIONS